3.6 Code table
3−135
L
9300 Servo PLC EN 5.1
Code InformationPossible settingsLCDCode Information
SelectionLenze
LCD
C0362 Sync cycle
g
System bus: Time interval between 2 sync telegrams
(in preparation)
1 {1 ms} 30
C0363 Sync corr 1 System bus: Sync correction increments
1 0.2 s/ms
2 0.4 s/ms
3 0.6 s/ms
4 0.8 s/ms
5 1.0 s/ms
C0365 DIS:CAN active
g
Input signal CAN active
0 CAN not active
1 CAN active
C0366 Sync response 1 System bus: Sync response
0 No response
1 Response to sync
No response
PLC responds to a sync telegram by sending the
CAN1_OUT object.
C0367 Sync Rx Id 128 System bus: Sync Rx identifier
Receive identifier of the sync telegram.
1 {1} 256
C0368 Sync Tx Id 128 System bus: Sync Tx identifier
Send identifier of the sync telegram.
1 {1} 256
C0369 Sync Tx time 0 System bus: CAN sync send telegram cycle
A sync telegram with the identifier of C0368 is sent
with the set cycle time.
0 {1} 65000
0 = Off
C0370 Gateway addr. 0 System bus: Activate SDO gateway remote
parameterisation
The SDO gateway cannot be used to read out codes
>C2000 or codes of the Inverter Drives 8400 and Servo
Drives 9400.
When selecting a setting 0, all code read/write
accesses will be redirected to the system bus device
with the corresponding node address.
The codes are accessed via the SDO1 parameter
channel of the target device.
0 {1} 63
0 = remote parameter setting deactivated
C0381 HeartProTime 0 System bus: Heartbeat (slave): HeartbeatProducerTime
Time interval for sending the "heartbeat" message.
Only relevant for setting C0352 = 3.
Additional information about the "heartbeat" function
can be found in the Manual for the function library
LenzeCanDSxDrv.lib.
0 {1 ms} 65535
C0382 GuardTime 0 System bus: Node Guarding (slave): NodeGuardTime
Time interval for the status request from the master.
Only relevant for setting C0352 = 4.
Additional information about the "node guarding"
function can be found in the Manual for the function
library LenzeCanDSxDrv.lib.
0 {1 ms} 65535