Lenze EVS9332xP Manual do Utilizador Página 209

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 334
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 208
Function library
Function blocks
3.5.30 Digital frequency processing (DFSET)
3−181
l
EDSVS9332P−EXT DE 2.0
Synchronisation mode
For the synchronisation, different modes are available which can be set under C0534.
C0534 Synchronisation mode Note
0 Synchronisation not active
1 Permanent synchronisation with direct correction of the angular
difference (counter−clockwise or clockwise rotation).
2 Permanent synchronisation with direct correction of the angular
difference (counter−clockwise or clockwise rotation).
A LOW−HIGH edge at DFSET−0−pulse activates a continuous
synchronisation.
10 One−time synchronisation with direct correction of the angular
difference (counter−clockwise or clockwise rotation).
A LOW−HIGH edge at DFSET−0−pulse activates a one−time
synchronisation.
11 One−time synchronisation with correction of the angular
difference in clockwise rotation.
A LOW−HIGH edge at DFSET−0−pulse activates a one−time
synchronisation.
12 One−time synchronisation with correction of the angular
difference in counter−clockwise rotation.
A LOW−HIGH edge at DFSET−0−pulse activates a one−time
synchronisation.
13 One−time synchronisation with correction of the angular
difference. The difference is determined between the setpoint
pulse and actual pulse and is corrected to the corresponding
direction of rotation according to the sign.
A LOW−HIGH edge at DFSET−0−pulse activates a one−time
synchronisation.
Vista de página 208
1 2 ... 204 205 206 207 208 209 210 211 212 213 214 ... 333 334

Comentários a estes Manuais

Sem comentários