Lenze PLC Designer R3-x Manual do Utilizador Página 58

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 159
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 57
Extending sample projects - adding devices
Create control configuration - bus system CAN
58
Lenze · Commissioning of Lenze drives · 1.3 EN - 06/2014
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
6. Give the inserted slaves suitable names (e.g. "Drive_vertical").
The names must …
only contain the characters "A ... Z", "a ... z", "0 ... 9" or "_";
must not begin with a digit.
You can enter a name by clicking the element.
Example:
Below the selected slave, the axis data are available in the form of an additional node.
L_LCB_AXIS_REF
( 115)
Connect a function block to the LC_Drive instance to establish a connection to the slave.
Transmitted process data are written automatically to the axis data. Hence, no manual
assignment of the process data to the application is required. Overview: The libraries for
controlling the inverters ( 82)
In order to be able to link the process data
manually (instead of the automatic link to
the L_LCB_Axis_REF instance), the Manual
I/O mapping option has to be activated.
Vista de página 57
1 2 ... 53 54 55 56 57 58 59 60 61 62 63 ... 158 159

Comentários a estes Manuais

Sem comentários