Lenze PLC Designer R3-x Manual do Utilizador Página 87

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 159
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 86
Lenze · Commissioning of Lenze drives · 1.3 EN - 06/2014 87
The L_DAC_DataConversion library
L_DAC_GetBitOfDWord - conversion block
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
11.3 L_DAC_GetBitOfDWord - conversion block
This function returns the status of an individual bit value within a "DWORD" value.
Inputs
Output
Function library: L_DAC_DataConversion
Runtime software licence: LPC 1x00 MPC 1x00 MPC 2xx0 MPC 3x00
L_DAC_GetBitofDWord
DWORD dwInput L_DAC_GetBitOfDWord BOOL
BYTE byBitNr
Identifier/data type Information/possible settings
dwInput
DWORD
Input signal
byBitNr
BYTE
Number (0 ... 31) of the bit of dwInput, the status of which is to be determined.
Identifier/data type Information/possible settings
L_DAC_GetBitOfDWord
BOOL
Output signal
TRUE if the respective bit of dwInput is TRUE.
Vista de página 86