L-force Controls | I/O System 1000
Networking via CAN system bus
Creating a network
Step 3 - Settings
7. Select the Insert machine application and add node control field if all available
devices are to be added automatically to the network as a node.
If the control field has been selected, the project is also assigned with a machine
application which is displayed in the project tree. The selected applications are
already implemented in the machine application.
In the Settings area, the default values given for Lenze devices do not need to be
changed.
All compatible network nodes which are below the network system module are
added to the network. If a device has several node interfaces of the same type,
a selection dialog appears.
All assigned network nodes are pre-assigned with addresses in ascending order.
With CAN, the minimum address is taken from the settings.
8. Press Next.
An info text appears.
You can either change the node addresses in the Engineer project or at the
hardware switches.
9. Press Complete.
The selected network is inserted into the marked element.