9300 Servo PLC
System blocks
2.7 DCTRL_DriveControl (node number 121)
2−25
L
9300 Servo PLC EN 5.0
2.7.7 Resetting TRIP (TRIP−RESET)
This function resets an active TRIP provided that the cause of malfunction is eliminated. If the cause
of malfunction is still active, there is no response.
The function can be controlled via the following 4 inputs (OR’d):
Control word CAN1_wDctrlCtr of SB CAN1_IN
Control word AIF_wDctrlCtrl of SB AIF1_IN
Control word C0135, bit 11
System variable DCTRL_bTripReset_b
Note!
The function can only be performed by the FALSE−TRUE edge of the signal resulting from the OR
operation!
A FALSE−TRUE edge cannot occur if one of the inputs is TRUE!
C0136/1 indicates the control word C0135. (^ 2−23)
2.7.8 Output of digital status signals
Via DCTRL_wStat a status word is output which consists of the signals generated from the SB
DCTRL_DriveControl and of signals from freely configurable SB inputs:
STAT
DCTRL_bImp_b
DCTRL_bNActEq0_b
DCTRL_bCInh_b
DCTRL_bStat1_b
DCTRL_bStat2_b
DCTRL_bStat4_b
DCTRL_bStat8_b
DCTRL_bWarn_b
DCTRL_bMess_b
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
DCTRL_bStateB0_b
DCTRL_bStateB2_b
DCTRL_b _bStateB3
DCTRL_b _bStateB4
DCTRL_bStateB5_b
DCTRL_bStateB14_b
DCTRL_bStateB15_b
DCTRL_DriveControl
DCTRL_wStat
C0150
Fig. 2−14 Output of the status word DCTRL_wStat