2.10 DIGITAL_IO (node number 1)
9300 Servo PLC
System blocks
2−40
L
9300 Servo PLC EN 5.0
2.10.2 Outputs_DIGITAL (digital outputs)
This SB conditions the digital signals and outputs them at terminals X5/A1 ... A4.
X5
Outputs_DIGITAL
1
0
C0118/1...4
A3
A1
A4
A2
1
DIGOUT_bOut1_b
DIGOUT_bOut4_b
DIGOUT_bOut3_b
DIGOUT_bOut2_b
C0444/1...4
Fig. 2−22 Outputs_DIGITAL
System variables
Variable Data type Signal type Address Display
code
Display
format
Note
DIGOUT_bOut1_b
Bool Binary
%QX1.0.0 C0444/1
bin
DIGOUT_bOut2_b
%QX1.0.1 C0444/2
DIGOUT_bOut3_b
%QX1.0.2 C0444/3
DIGOUT_bOut4_b %QX1.0.3 C0444/4
Electrical data of the output terminals
Terminal Use Measuring range
X5/A1
Freely assignable
LOW level:
HIGH level:
Output current:
Delay times:
0 ... +4 V
+13 ... +30 V
Max. 50 mA per output
(external resistance 480 at 24 V)
300 s with rising edge
100 s with falling edge
X5/A2
X5/A3
X5/A4
X5/39 Ground (GND) of digital inputs and outputs
The terminal polarity of the outputs X5/A1 ... A4 can be configured under C0118:
Code LCD
Possible settings
Info
Lenze Selection
C0118 DIGOUT pol Terminal polarity
0 HIGH active
1 LOW active
1 0 X5/A1
2 0 X5/A2
3 0 X5/A3
4 0 X5/A4