9300 Servo PLC
System blocks
2.12 MCTRL_MotorControl (node number 131)
2−63
L
9300 Servo PLC EN 5.0
The fault memory (C0168/x) stores the error messages with an offset which indicates the type of the
response:
No. of the error message Type of response
0xxx TRIP
1xxx Message
2xxx Warning
3xxx FAIL−QSP
Example: C0168/1 = 2061
x061:
The current error (subcode 1 of C0168) is a communication error (error message "CE0"/No.
"x061") between the AIF module and the PLC.
2xxx:
The response is a warning.
Tip!
Occurring faults generally do not affect the operating ability of the PLC!
For more detailed information about the error sources detected by the PLC as well as causes
& remedies, please refer to the appendix (chapter 3.5).
(^ 3−8)