Lenze EtherCAT control technology Manual do Utilizador Página 137

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 204
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 136
DMS 3.1 EN 01/2011 TD17 L 137
Control technology | EtherCAT communication manual
Diagnostics
Diagnostics with the »PLC Designer«
11.2.3 The global variable wState
When Motion nodes are used for control, »PLC Designer« displays the current status of the
control acceleration in the global variable wState of the "AxisGroup" structure.
The value of the wState variable has the following meaning:
Example for a faulty acceleration:
Status of the AxisGroup State of the system
wState = 0 •Initial state
•Project loaded
PLC in stop
wState = 1...99 System is starting up
•Project loaded
•PLC started
wState = 100 System has started up successfully
wState > 1000 Error occurred during startup, compare error message in
g_strBootupError
Vista de página 136
1 2 ... 132 133 134 135 136 137 138 139 140 141 142 ... 203 204

Comentários a estes Manuais

Sem comentários