7 Commissioning of the system
7.3 Detailed description of the commissioning steps
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7.3.4.2 i700 parameter management in »EASY Starter«
For parameter management in »EASY Starter«, you must insert the Lenze Controller and the Servo-
Inverter i700 into the device list with the help of the button.
[7-3] Parameter set transfer with »EASY Starter«
With »EASY Starter«, there are two application cases for parameter management:
A. Storing the current Servo-Inverter i700 parameter setting in the Lenze Controller with mains
failure protection:
Select the Lenze Controller from the device list.
With the button or the <F6> function key, store the parameter set in the controller so that
it is saved there even in the event of a power failure. (To this end, the controller uploads all
the parameter sets of the lower-level i700 servo inverter.)
After the system has been switched off and then switched on again. the controller transfers
the parameter sets to the i700 inverter again.