Lenze EVS9332xS Manual do Utilizador Página 104

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 264
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 103
Function library
Function blocks
3.2.20 Speed conversion (CONVPP)
3−52
l
EDSVS9332S−EXT EN 2.0
3.2.20 Speed conversion (CONVPP)
Purpose
Conversion of a speed signal with dynamic fraction.
C O N V P P 1
C O N V P P 1 -
O U T
C O N V P P 1 - I N
C 1 2 5 3
C 1 2 5 0
C O N V P P 1 - N U M
C 1 2 5 4 / 1
C 1 2 5 1 / 1
C O N V P P 1 _ D E N
C 1 2 5 4 / 2
C 1 2 5 1 / 2
1
x
y
Fig. 3−50 Speed conversion (CONVPP1)
Signal
Source Note
Name Type DIS DIS format CFG List
CONVPP1−IN phd C1253 dec [rpm] C1250 4
CONVPP1−NUM ph C1254/1 dec [inc] C1251/1 3 Numerator
CONVPP1−DEN ph C1254/2 dec [inc] C1251/2 3 Denominator (with absolute value generation)
CONVPP1−OUT phd Without limitation, remainder considered
Function
Caution!
The conversion result is not limited. The result must therefore not exceed ±32767.
l The speed signal at CONVPP1−IN is evaluated using the factor from C1251/1 / C1251/2.
Vista de página 103
1 2 ... 99 100 101 102 103 104 105 106 107 108 109 ... 263 264

Comentários a estes Manuais

Sem comentários