Function library
Function blocks
3.2.27 Digital frequency processing (DFSET)
3−79
l
EDSVS9332S−EXT EN 2.0
Synchronisation mode
For the synchronisation, different modes are available which can be set under C0534.
C0534 Synchronisation mode Note
0 Inactive Function inactive
1 Continuous synchronisation with correction in the shortest
possible way
2 Continuous synchronisation with correction in the shortest
possible way
A LOW−HIGH edge at DFSET−0−Pulse initiates continuous
synchronisation
10 One−time synchronisation, an angular deviation is corrected in
the shortest possible way
11 One−time synchronisation, an angular deviation is corrected in
CW direction
A LOW−HIGH edge at DFSET−0−Pulse initiates a one−time
synchronisation
12 One−time synchronisation, an angular deviation is corrected in
CCW direction
13 One−time synchronisation, an angular difference is determined
between setpoint pulse and actual pulse and is corrected to the
corresponding direction of rotation according to the sign
Code C0528/1 displays the number of increments (angular difference) between the setpoint pulse
and the actual pulse before the synchronisation.