Function library
Function blocks
3.2.41 Motor phase failure detection (MLP)
3−122
l
EDSVS9332S−EXT EN 2.0
3.2.41 Motor phase failure detection (MLP)
Purpose
Motor phase monitoring.
MLP1
Fig. 3−105 Motor phase failure detection (MLP1)
Code
LCD
Possible settings
Important
Lenze Selection
C0597 MONIT LP1 3 0 Trip
2 Warning
3 Off
Conf. LP1
Configuration of motor phase failure
monitoring
C0599 LIMIT LP 1 5.0 1.0 {0.1} 10.0 Current limit LP1
Current limit for motor phase failure
monitoring
Function
Detailed descriptions of monitoring systems and error messages can be found in the system manual,
document number EDSVS9332P.
The function block MLP1 must be entered in the processing table if the motor phase failure detection
is to be used.