Function library
Function blocks
3.2.23 Control of the drive controller (DCTRL)
3−59
l
EDSVS9332S−EXT EN 2.0
3.2.23.2 Operation inhibit (DISABLE)
In this state the drive cannot be started by the "Controller enable" command. The power output
stages are inhibited. All controllers are reset.
l The function can be controlled by three inputs
Control word CAN−CTRL bit 8 of CAN−IN1
Control word AIF−CTRL bit 8 of AIF−IN
Control word C0135 bit 8
l All inputs are linked by an OR−operation.
l C0136/1 displays the control word C0135
3.2.23.3 Controller inhibit (CINH)
The power output stages are inhibited. All controllers are reset.
l The function can be controlled by seven inputs:
Terminal X5/28 (LOW = controller inhibit)
Control word CAN−CTRL bit 9 of CAN−IN1
Control word AIF−CTRL bit 9 of AIF−IN
Control word C0135 bit 9
MONIT−TRIP (HIGH = in the function block MONIT a monitoring function configured to TRIP
has been triggered)
Free input DCTRL−CINH1
Free input DCTRL−CINH2
l All inputs are linked by an OR−operation.
l C0136/1 displays the control word C0135
) Note!
If an LU message or an OU message occurs, the CINH signal will not be set.
3.2.23.4 TRIP−SET
The drive is controlled into the state under code C0581 and indicates EEr (external monitoring).
l The function can be controlled by four inputs
Control word CAN−CTRL bit 10 of CAN−IN1
Control word AIF−CTRL bit 10 of AIF−IN
Control word C0135 bit 10
Free input DCTRL−TRIP−SET
l All inputs are linked by an OR−operation.
l C0136/1 displays the control word C0135