Vista de página 85
Function library
Function blocks
3.2.12 Analog signal changeover switch (ASW)
3−34
l
EDSVS9332S−EXT EN 2.0
A S W 4 - I N 1
C 1 1 6 7 / 1
1
0
C 1 1 6 7 / 2
A S W 4 - S E T
A S W 4 - I N 2
A S W 4
A S W 4 - O U T
C 1 1 6 8
C 1 1 6 5 / 1
C 1 1 6 5 / 2
C 1 1 6 6
Fig. 3−32 Changeover switch for analog signals (ASW4)
Signal
Source Note
Name Type DIS DIS format CFG List Lenze
ASW4−IN2 a C1167/1 dec [%] C1165/1 1 1000
ASW4−IN1 a C1167/2 dec [%] C1165/2 1 1000
ASW4−SET d C1168 bin C1166 2 1000
ASW4−OUT a
Function
This FB is controlled via the binary input. Depending on the input signal, different signals are sent to
the output:
l If a HIGH signal is applied at the binary input, the signal which is applied at the ASWx−IN2
input is sent to the output.
l If a LOW signal is applied, the signal which is applied at the ASW−IN2 input is sent to the
output.