Lenze EVS9332xS Manual do Utilizador Página 190

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 264
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 189
Function library
Function blocks
3.2.47 Oscilloscope function (OSZ)
3−138
l
EDSVS9332S−EXT EN 2.0
3.2.47 Oscilloscope function (OSZ)
Purpose
Detection of any measured variable (e. g. speed setpoint, actual speed, torque etc.). They are
visualised in Global Drive Control.
Supports the commissioning of controllers and the troubleshooting.
OSZ-CHANNEL1
OSZ
OSZ-DIG-TRIGGER
C0734
C0735
C0737
C0730
C0731
C0736
C0739
C0749
C0744
C0738
C0740
C0741
measuring value
memory
1
2
3
4
CTRL
OSZ-CHANNEL2
OSZ-CHANNEL3
OSZ-CHANNEL4
C0733/1
C0732/1
C0732/2
C0732/3
C0732/4
fb_osz
Fig. 3−124 Oscilloscope function (OSZ)
Signal
Source Note
Name Type DIS DIS format CFG List Lenze
OSZ CHANNEL1 a C0732/1 1
OSZ CHANNEL2 a C0732/2 1
OSZ CHANNEL3 a C0732/3 1
OSZ CHANNEL4 a C0732/4 1
OSZ−DIG−TRIGGER d C0733/1 2
Function
The FB has three function units:
l Trigger check
Monitoring of the digital trigger source for a valid trigger event
l Processing of the measured signal
Linking the measurement inputs
Calculating the time base
Monitoring of the analog trigger source for a valid trigger event.
l Measuring value memory
Scaling the ring buffer
Filing the measured data in the ring buffer
Saving the measuring points for image generation
Vista de página 189
1 2 ... 185 186 187 188 189 190 191 192 193 194 195 ... 263 264

Comentários a estes Manuais