Function library
Function blocks
3.2.38 Limiting element (LIM)
3−101
l
EDSVS9332S−EXT EN 2.0
3.2.38 Limiting element (LIM)
Purpose
This FB is used to limit signals to adjustable value ranges.
LIM1
LIM1-OUT
LIM1-IN
C0633
C0630
C0631
C0632
Fig. 3−96 Limiting element (LIM1)
Signal
Source Note
Name Type DIS DIS format CFG List Lenze
LIM1−IN1 a C0633 dec [%] C0632 1 1000
LIM1−OUT a
Function
l If the input signal exceeds the upper limit (C0630), the upper limit is effective.
l If the input signal falls below the lower limit (C0631), the lower limit is effective.
Tip!
The lower limit (C0631) must be smaller than the upper limit (C0630).