Lenze DSD Manual do Utilizador Página 211

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 496
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 210
Lenze · Drive Solution Designer · Manual · DMS 4.2 EN · 12/2013 · TD23 211
7Applications
7.22 Winding drive for rewinder/unwinder
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7.22.5 Checking emergency-off scenarios
DSD is only partially able to check emergency-off scenarios. The user interface and the DSD protocol
display a note.
[7-234] Motor diagram: winder torque (diameter-related)
The Application Tuner may help with the required additional checks. Application Tuner ( 59)
Note!
The torque required for emergency stop is greater than the drive torque available.
The torque required for emergency stop is calculated and represented in the diame-
ter-dependent torque diagram of the motor. The calculation is based on the emergen-
cy stop time, a linear motion profile, and a tensile force = 0 N (material crack).
The thermal utilisation of the drive components is not checked.
Braking circuits are not dimensioned.
Description
Torque required for emergency stop
Max. available drive torque
Vista de página 210
1 2 ... 206 207 208 209 210 211 212 213 214 215 216 ... 495 496

Comentários a estes Manuais

Sem comentários