8 Motion design
8.3 Predefined motion profile according to operating mode
274
Lenze · Drive Solution Designer · Manual · DMS 4.2 EN · 12/2013 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
8.3.5 Description of the data for the entry
8.3.5.1 Max. velocity
8.3.5.2 Speed
8.3.5.3 Variable payload mass
8.3.5.4 Torque load
8.3.5.5 Variable force associated with the application
8.3.5.6 Basic setting of motion profile
8.3.5.7 Relative operating time
Parameter Description
v
max
Max. velocity of the application.
Parameter Description
n Speed of application.
Parameter Description
m
var,L
Mass of the payload, changeable.
Parameter Description
m
L
Required torque which must be provided.
Parameter Description
F
var,App
Required force of the application, changeable.
Parameter Description
Use The values of the basic settings are marked grey and cannot be altered.
Change The values of the basic setting can be altered.
Parameter Description
OT The relative operating time is the ratio of the duration of the load phase to that of the idle phase.
• The designation of the operating mode is supplemented by the relative operating time, e. g.
"S3
-25 %".