7.2 INPUT FUSING & DISCONNECT REQUIREMENTS
A circuit breaker or a disconnect switch with fuses must be provided in accordance with the
National Electric Code (NEC) and all local codes. Refer to the following tables for proper
fuse/circuit breaker ratings and wire sizes.
INPUT FUSE & CIRCUIT BREAKER RATINGS
208/240 Vac, 1 phase 208/240 Vac, 3 phase 400/480 Vac, 3 phase 480/590 Vac, 3 phase
MODEL RATING MODEL RATING MODEL RATING MODEL RATING
TF205Y 10 A TF205Y 10 A TF405 10 A
TF210Y 15 A TF210(Y) 10 A TF410 10 A TF510 10 A
TF215Y 20 A TF215(Y) 12 / 10 A TF415 10 A
TF220Y 25 / 20 A TF220(Y) 15 / 12 A TF420 10 A TF520 10 A
TF230Y 30 / 25 A TF230(Y) 20 / 15 A TF430 10 A TF530 10 A
TF250 30 / 25 A TF450 15 A TF550 12 A
TF275 45 / 40 A TF475 20 A TF575 20 A
TF2100 50 / 50 A TF4100 30 / 25 A TF5100 20 A
NOTE
Applicable national and local electrical codes take precedence over
recommendations in these tables.
Use UL Class CC fast-acting, current limiting type fuses. Select fuses
with low I2T values, rated at 200,000 AIC. Recommended fuses are
Bussman KTK-R, JJN, and JJS. Similar fuses with equivalent ratings by
other manufacturers may also be acceptable.
WARNING!
This product can cause a DC current in the protective conductor. Where
a residual current device (RCD) is used for protection in case of direct or
indirect contact, only an RCD of Type B is allowed on the supply side of
this product. Otherwise, another protective measure shall be applied, such
as separation from the environment by double or reinforced insulation, or
isolation from the supply system by a transformer.
Observe the following when using RCDs:
1. Only install the RCD between the supply mains and drive controller.
2. The RCD can be activated by:
capacitive leakage currents between the cable screens during
operation (especially with long, screened motor cables)
connecting several drives to the mains at the same time
additional RFI filters