P51 SOFTWARE VERSION
This displays the software version number for the control board software. This information is
useful when contacting the factory for programming or troubleshooting assistance.
The software version is displayed in two parts which alternate. The first part is the software
version, and the second part is the revision number. For example, if the display shows "106"
and "-02" this indicates that the drive contains the second revision of version 106 software.
P52 DC BUS VOLTAGE
This displays the DC bus voltage in percent of nominal. Nominal DC bus voltage is determined
by multiplying the drive’s nameplate input voltage rating by 1.4.
P53 MOTOR VOLTAGE
This displays the output voltage in percent of the drive’s nameplate output voltage rating.
P54 MOTOR LOAD
This displays the motor load in percent of the drive’s output current rating.
P55 0-10 VDC ANALOG INPUT
This displays the level of the 0-10 VDC analog input signal at TB-5. A reading of 100%
indicates a 10 VDC input at TB-5.
NOTE
If the -10 to +10 VDC bipolar input is used, this parameter will display 0% at -10
VDC, 50% at 0 VDC, and 100% at +10 VDC.
P56 4-20 mA ANALOG INPUT
This displays the level of the 4-20 mA analog input signal at TB-25. A reading of 20% indicates
a 4 mA input at TB-25, and a reading of 100% indicates a 20 mA input at TB-25.
P57 TERMINAL STRIP STATUS
This indicates the status of several terminals using the vertical segments of the LED display.
An illuminated segment indicates that the particular terminal is closed with respect to TB-
2. The CHARGE RELAY is not a terminal, and should always be illuminated. Refer to the
diagram herein.
CHAR G E
RELAY
TB-1
TB-13D
TB-13A
TB-13B
TB-15
TB-14
TB-13C