Lenze EVS9332xP Manual do Utilizador Página 140

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 139
Wiring of the standard device
Control terminals
Device variant without "Safe torque off" function
5
5.8
5.8.3
5.8−4
EDSVS9332P EN 5.0−07/2013
5.8.3 Device variant without "Safe torque off" function
Internal voltage supply
ƒ For the supply of the digital inputs (X5/E1 ... X5/E5) you have to set a
freely assignable digital output (e. g. X5/A1) permanently to HIGH
level.
ƒ For the supply of the analog inputs (X6/1, X6/2 and X6/3, X6/4) you
have to set a freely assignable analog output (e. g. X6/63) permanently
to HIGH level.
GND2 +24V
E5
A2 A3 A4 ST1
ST2
59
39
3k
47k
50mA
50mA
50mA
50mA
X5
28
E1 E2 E3 E4
3k
3k
3k
3k
3k
S1
A1
X3
X6
12
3
4
242R
1
2
3
4
5
6
100k
100k
100k
100k
3.3nF
GND1 GND1
7762
63
AIN1 AIN2
AOUTx
AOUT2
AOUT1
1
3
247
10k 10k
9300vec201
Fig. 5.8−3 Wiring of digital and analog inputs/outputs for internal voltage source
S1 Controller enable
NO contact or NC contact
Z
Load
Minimum wiring required for operation
Terminal assignment in the Lenze setting: 5.8−9
Supply via external voltage source
GND2 +24V
E5
A2 A3 A4ST1
ST2
59
39
3k
47k
50mA
50mA
50mA
50mA
X5
28
E1 E2 E3 E4
3k
3k
3k
3k
3k
DC 24 V
(+18 V … +30 V)
S1
+
A1
X3
GND1 GND1
X6
12
3
4
7762
63
242R
1
2
3
4
5
6
100k
100k
100k
100k
3.3nF
AIN1 AIN2
AOUTx
AOUT2
AOUT1
1
3
247
10k 10k
9300std077
Fig. 5.8−4 Wiring of digital and analog inputs/outputs for external voltage source
S1 Controller enable
NO contact or NC contact
Z
Load
Minimum wiring required for operation
Terminal assignment in the Lenze setting: 5.8−9