Lenze EVS9332xP Manual do Utilizador Página 151

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 150
Wiring of the standard device
Wiring of the feedback system
Important notes
5
5.10
5.10.1
5.10−1
EDSVS9332P EN 5.0−07/2013
5.10 Wiring of the feedback system
5.10.1 Important notes
The feedback signal can either be supplied via input X7 or via input X8.
ƒ At X7 a resolver can be connected.
ƒ At X8 an encoder can be connected.
– Incremental encoder TTL
– SinCos encoder
– SinCos encoder with serial communication (single−turn or multi−turn)
The resolver or encoder signal for slave drives can be output at the digital
frequency output X10.
Note!
ƒ We recommend to use Lenze system cables for wiring.
ƒ For self−made cables only use cables with shielded cores
twisted in pairs.
Installation material required from the scope of supply:
Description Use Quantity
Protective cover Protection for unused Sub−D connections 4
Vista de página 150