Lenze EVS9332xP Manual do Utilizador Página 442

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 441
Appendix
Index
13
13.2
13.2−4
EDSVS9332P EN 5.0−07/2013
Monitoring, 8.2−1
bus off, 8.2−3
Current load of controller, Ixt monitoring, 8.2−5
current load of the motor, I2 x t monitoring, 2.2−1, 8.2−7
DC−bus voltage, 8.2−11
Earth fault in motor cable (OC2), 8.2−4
Exceeding of the maximum speed (NMAX), 8.2−4
External error (EEr), 8.2−11
Failure of a motor phase (LP1), 8.2−4
Heatsink temperature, 8.2−10
Monitoring times for process data input objects, 8.2−3
motor cable overcurrent (OC1), 8.2−4
motor temperature, 8.2−6
reset node, 8.2−3
responses, 8.2−1
FAIL−QSP, 8.2−1
message, 8.2−1
TRIP, 8.2−1
warning, 8.2−1
Monitoring functions
Motor temperature, 2.2−1
Overview, 8.31
responses, 8.2−1
Monitoring times for process data input objects, 8.2−3
Monitorings
configuration, 8.31
possible fault responses, 8.31
Motor, thermal monitoring, with PTC thermistor, 6.5−12,
6.5−13
motor, Thermal monitoring, Sensorless, 2.2−1
Motor cable, 5.2−8, 5.3−1
Cable cross−section, 5.2−9
for trailing cable, 5.2−9
Influence of the length, 5.2−8
length, 3.1−2
max. length, 5.2−7
permanently installed, 5.2−9
permissible length, 5.2−8
Specification, 5.2−8
Motor cable overcurrent (OC1), 8.2−4
Motor connection, 3.1−2
Motor monitoring, 2.2−1
Motor potentiometer, 8.5−14
Motor protection, 2.3−2
Motor stator resistance, 8.5−6
Motor temperature, monitoring, 8.2−6
Mounting conditions
Dimensions, 3.1−2
Free spaces, 3.1−2
Mounting place, 3.1−2
Mounting position, 3.1−2
Weights, 3.1−2
Mounting place, 3.1−2
Mounting position, 3.1−2
N
Nameplate, 1.1−3
Network of several drives, Function, 10.1−1
Noise−optimised operation, 8.5−3
O
Operating conditions, 3.1−1, 7.2−1
Ambient conditions
Climatic, 3.1−1
Mechanical, 3.1−2
ambient conditions, electrical, 3.1−2
Mounting conditions
Dimensions, 3.1−2
Free space, 3.1−2
Mounting place, 3.1−2
Mounting position, 3.1−2
Weight, 3.1−2
Operating mode of the motor control, 8.5−2
Operating status, display, 9.2−1
Operation, at earth−leakage circuit breaker, 5.2−3
Operation on public supply systems, EN 61000−3−2, 5.2−1
Optimisation of the controller and mains load, 5.2−5
Output signals
Analog, Configuration, 6.9−4
Digital, Configuration, 6.9−2
Outputs
Analog, 6.9−4
Digital, 6.9−2
Overview, Accessories, 12−1
Overvoltage threshold, DC−bus voltage, 8.2−11
P
Parameter sets, Management, 6.12−1
Parameter setting, 7−1
code, 7.1−1
with bus system, 7.1−2
With XT EMZ9371BC keypad, 7.2−1
Vista de página 441