
Commissioning
Parameter set management
Saving of parameter set
6
6.12
6.12.1
6.12−2
EDSVS9332P EN 5.0−07/2013
A parameter set transfer can only be executed if controller inhibit is
activated.
Danger!
Uncontrolled motor movement possible.
The controller is reinitialised by the parameter set transfer from
the PC to the controller. System configurations and terminal
assignments may be different.
Possible consequences:
ƒ Severe injuries to persons in or near the machine.
ƒ The machine is damaged or destroyed.
Protective measures:
ƒ Make sure that your wiring and drive configuration comply
with the settings of the parameter set.
ƒ Use terminal X5/28 or the STOP function in GDC as the source
for controller inhibit.
How to transfer a parameter set to the controller:
1. Execute Drive parameters è Write parameter set to drive.
– Alternatively the command can be executed via key "F5".
2. Open the "Load / Save" menu in the parameter menu and save the
parameter set safe against mains failure with C0003 = 1.
Save parameter set to the
controller
Comentários a estes Manuais