Configuration
Overview of monitoring functions
8
8.3
8.33
EDSVS9332P EN 5.0−07/2013
x151 P01 Limit switch negative = LOW Internal C1285/1 ü l
x152 P02 Limit switch positive = LOW Internal C1285/2 ü l
x154 P04 Position limit exceeded in negative direction Internal C1285/3 ü l
x155 P05 Position limit exceeded in positive direction Internal C1285/4 ü l
x156 P06 No reference Internal C1287/1 ü l
x157 P07 Parameter set mode absolute Internal C1291/1 ü l
x158 P08 Actual reference dimension offset outside position limits Internal C1291/2 ü l
x159 P09 Impermissible programming Internal C1291/3 ü l
x162 P12 Encoder range exceeded Internal C1288/1 ü l
x164 P14 1. following error tolerance > C1218/1 Internal C1286/1 ü ü l ü
x165 P15 2. following error tolerance > C1218/2 Internal C1286/2 ü ü ü l
x167 P17 Control error of touch probe Internal C1289/1 ü ü l ü
x168 P18 Internal limitation (display area, position limits, speeds) Internal C1289/2 ü ü l ü
Representation of the error number:
x 0 = TRIP, 1 = message, 2 = warning
E. g. "2091": An external monitoring has triggered EEr warning
1)
Setting only permitted by Lenze service