Lenze EVS9332xP Manual do Utilizador Página 296

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 295
Configuration
Basic configurations
8
8.5
8.5−30
EDSVS9332P EN 5.0−07/2013
IMPORTANTPossible settingsCode
SelectionLenzeDesignationNo.
C0685 CMP2−
FUNCTION
1 1
2
3
4
5
6
IN1 = IN2
IN 1 > IN2
IN 1 < IN2
|IN1| = |IN2|
|IN1| > |IN2|
|IN1| < |IN2|
CMP2
Function selection
l Comparison of inputs IN1
and IN2
See system
manual
(extension)
C0686 CMP2−
HYSTERESIS
1.00 0.00 {0.01 %} 100.00 CMP2
Hysteresis
C0687 CMP2−
WINDOW
1.00 0.00 {0.01 %} 100.00 CMP2
Window
C0688
® Selection list 1
CMP2
Configuration of analog input
signals
1 CMP2−IN1 1000 FIXED0%
2 CMP2−IN2 1000 FIXED0%
C0689
) −199.99 {0.01 %} 199.99 CMP2
Display of analog input signals
1 CMP2−IN1
2 CMP2−IN2
C0690 CMP3−
FUNCTION
1 1
2
3
4
5
6
IN1 = IN 2
IN 1 > IN2
IN 1 < IN2
|IN1| = |IN2|
|IN1| > |IN2|
|IN1| < |IN2|
CMP3
Function selection
l Comparison of inputs IN1
and IN2
See system
manual
(extension)
C0691 CMP3−
HYSTERESIS
1.00 0.00 {0.01 %} 100.00 CMP3
Hysteresis
C0692 CMP3−
WINDOW
1.00 0.00 {0.01 %} 100.00 CMP3
Window
C0693
® Selection list 1
CMP3
Configuration of analog input
signals
1 CMP3−IN1 1000 FIXED0%
2 CMP3−IN2 1000 FIXED0%
C0694
) −199.99 {0.01 %} 199.99 CMP3
Display of analog input signals
1 CMP3−IN1
2 CMP3−IN2
C0700
ANEG1−IN 19523 FCODE−472/3 ® Selection list 1 ANEG1
Configuration − analog input
signal
See system
manual
(extension)
C0701 ANEG1−IN ) −199.99 {0.01 %} 199.99 ANEG1
Display of analog input signal
C0703
ANEG2−IN 1000 FIXED0% ® Selection list 1 ANEG2
Configuration − analog input
signal
See system
manual
(extension)
C0704 ANEG2−IN ) −199.99 {0.01 %} 199.99 ANEG2
Display of analog input signal
Vista de página 295
1 2 ... 291 292 293 294 295 296 297 298 299 300 301 ... 444 445

Comentários a estes Manuais