EDS84DMOTCAN EN 3.0 - 11/2011 L 47
Communication manual 8400 motec CANopen
Process data transfer
Port interconnection of the process data objects (PDO)
8.2 Port interconnection of the process data objects (PDO)
The preconfigured port interconnection of the process data objects is activated by setting
code C00007 = 40: Network (MCI/CAN).
How to freely configure the port interconnection in the »Engineer«:
1. Under the Process data object tab, click the Go to application button.
2. The Ports tab displays the port blocks CAN1_IN/CAN2_IN and CAN1_OUT/
CAN2_OUT.
Note!
The »Engineer« screenshots shown on the following pages are only examples for
the setting sequence and the resulting screens.
Depending on the software version of the controller and of the »Engineer«
software installed, the screenshots may deviate from your »Engineer«
representation.
Vista de página 46