5 Motor interface
5.1 General information
120
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Overview of motor data
Parameter Info Lenze setting *
Value Unit
C00052 Motor voltage - V
C00054 Motor current - A
C00057/1 Maximum torque - Nm
C00057/2 Motor reference torque - Nm
C00059 Motor - number of pole pairs -
C00060 Rotor position -
C00079 Mutual motor inductance - mH
C00081
Rated motor power kW
C00082 Motor rotor resistance - Ohm
C00083 Motor rotor time constant - ms
C00084
Motor stator resistance Ohm
C00085
Motor stator leakage inductance mH
C00087
Rated motor speed rpm
C00088
Rated motor current A
C00089
Rated motor frequency Hz
C00090
Rated motor voltage V
C00091
Motor cosine phi
C00092 Motor magnetising current - A
C00128/1
Therm. time constant coil min
C00128/2
Therm. time constant plates min
C00273/1
Motor moment of inertia kg cm²
C01190
Motor thermal sensor
C01191/1
Spec. characteristic: temperature °C
C01191/2 Spec. characteristic: temperature °C
C01192/1
Spec. characteristic: resistance Ohm
C01192/2 Spec. characteristic: resistance Ohm
Greyed out = display parameter * depending on the selected motor type
Note!
If the motor has been selected via the »Engineer« motor catalogue, or if the motor data
have been adapted offline in »Engineer«, all motor data have to be transferred to the
controller afterwards when an online connection has been established and have to be
saved in the memory module with mains failure protection (device command C00002
=
"11: Save start parameters").