Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 719
14 Parameter reference
14.1 Structure of the parameter descriptions
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
14.1.4 Parameter attributes
Description structure
The table footers contain the parameter attributes:
Meaning of the attributes
Scaling factor
The "scaling factor" is important for the parameter access via a bus system:
14.1.5 Abbreviations used in parameter & selection texts
Since the character length of the parameter and selection texts is limited, the following
abbreviations are used:
Read access Write access CINH PLC STOP No transfer
Attribute Meaning
Read access Read access to parameter possible.
Write access Write access to parameter possible.
• Please also observe the following attributes:
CINH Parameter value can only be changed when the
controller is inhibited.
PLC STOP Parameter value can only be changed when the
application is stopped.
No transfer The parameter is not transferred to the regenerative power supply module when the
command Download parameter set
is executed.
Read value (via bus system) Scaling factor Indicated value (Engineer)⋅=
Abbreviation Meaning
CAN module CANopen communication module (type E94AYCCA)
ENP Electronic nameplate
Ethernet module Ethernet communication module (type E94AYCEN)
MXI1 Module eXtension Interface 1 - module slot for extension 1
MXI2 Module eXtension Interface 2 - module slot for extension 2