Lenze 9400 Manual do Utilizador Página 184

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 954
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 183
5 Motor interface
5.6 V/f control (VFCplus)
184
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
[5-17] Voltage boost at linear/square-law V/f characteristic
Short overview: Parameters for voltage boost
Tip!
For magnetising the motor, consider a sufficient time from the controller enable to the
start of the speed ramp function generator.
The bigger the motor the longer the time required for magnetisation. A motor with a
power of 90 kW requires up to 2 seconds.
C00090: Rated motor voltage
C00951: V/f base frequency
U
0
0
C00951
C00090
f
soll
U
Boost
0
0
C00951
f
soll
U
C00090
U
Boost
Parameter Info Lenze setting
Value Unit
C00960 VFC: V/f voltage boost 0 V
Vista de página 183