C02542
C02543
C02544
C02545
C02547
Parameter | Name:
C02542 | Load reference speed
Data type: UNSIGNED_32
Index: 22033
d
= 5611
h
Drive interface
Display range (min. value | unit | max. value)
0.000 rpm 4294967.295
Read access Write access CINH PLC STOP No transfer Scaling factor: 1000
Parameter | Name:
C02543 | Load reference torque
Data type: UNSIGNED_32
Index: 22032
d
= 5610
h
Drive interface
Display range (min. value | unit | max. value)
0.000 Nm 4294967.295
Read access Write access CINH PLC STOP No transfer Scaling factor: 1000
Parameter | Name:
C02544 | Reference speed
Data type: INTEGER_32
Index: 22031
d
= 560F
h
From software version V1.5
Drive interface
Display range (min. value | unit | max. value)
-214748.3647 Unit/s 214748.3647
Read access Write access CINH PLC STOP No transfer Scaling factor: 10000
Parameter | Name:
C02545 | Reference S-ramp time
Data type: UNSIGNED_32
Index: 22030
d
= 560E
h
From software version V7.0
Drive interface
Setting range (min. value | unit | max. value) Lenze setting
0.000 s 2147483.647 0.001 s
Read access Write access CINH PLC STOP No transfer Scaling factor: 1000
Parameter | Name:
C02547 | DI_dnState
Data type: INTEGER_32
Index: 22028
d
= 560C
h
Bit coded status of the drive interface.
Display range (min. value | unit | max. value)
-2147483648 2147483647
Read access Write access CINH PLC STOP No transfer Scaling factor: 1