Lenze 9400 Manual do Utilizador Página 470

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 954
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 469
11 Basic drive functions
11.6 Homing
470
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Mode 1031: DS402 homing method 31
Reserved: no homing is executed.
Mode 1032: DS402 homing method 32
Reserved: no homing is executed.
Mode 1033: DS402 homing method 33
Procedure:
1. Movement in negative direction with profile data set 1 and activation of the touch probe
detection.
2. The following positive edge of the touch probe sensor sets the reference.
3. Absolute positioning to target position (C02643
) with profile data set 2 (if C02641 ="0").
Mode 1034: DS402 homing method 34
Procedure:
1. Movement in positive direction with profile data set 1 and activation of the touch probe
detection.
2. The following positive edge of the touch probe sensor sets the reference.
3. Absolute positioning to target position (C02643
) with profile data set 2 (if C02641 ="0").
Touch probe/zero pulse
1
0
Touch probe/zero pulse
1
0
Vista de página 469
1 2 ... 465 466 467 468 469 470 471 472 473 474 475 ... 953 954

Comentários a estes Manuais

Sem comentários