11 Basic drive functions
11.11 Limiter
506
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
11.11.1.1 Interface to the safety module
For the simple connection of the safety module to the application, the transmission of the currently
valid safety requirement(s) is effected in the form of a bit coded control signal via the following
interface:
[11-25] Interface to connect the safety module to the basic function "Limiter"
It is also possible to make several requirements at the same time via the control signal, e.g.
manual jog with limited increment and limited speed 2.
If no safety module is connected, the control signal can also be generated by means of a
converter block (FB L_DevSMControlEncoder).
LS_SafetyModuleInterface
SMI_dwControl
LS_Limiter
LIM_dwControl