Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 407
11 Basic drive functions
11.5 Manual job, encoderless
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
11.5 Manual job, encoderless
This function extension is available from software version V7.0!
The basic function "Manual jog (OL)", which is implemented in the motor control system of the drive
controller, enables the user to operate the drive without control
(i.e. "open loop", encoderless) and
independently of the selected operating mode:
If the motor is asynchronous, the speed depends on the load.
A synchronous motor turns with a prescribed field frequency.
The basic function "Manual jog (OL)"
is based on the I-rotation test mode and is especially suitable for the operation of synchronous
motors. There is a corresponding dialog box in »Engineer«
•is not
identical with sensorless operation of synchronous machines. In the basic function
"Manual jog (OL)", neither parameters relevant to the motor model nor parameters relevant to
the motor type are used
can be activated and controlled by means of process data (system block inputs) or by accessing
codes (e.g. via keypad).
Uses of "Manual job, encoderless"
Test of hardware (e.g. connection system, rotating field and motor cables) during initial
commissioning and during servicing
Movement of the drive or machine to a service position in the event of defective encoder
feedback
Functional test of the discretely structured feedback system of a torque or linear motor.
Danger!
In this basic function, the extent of the useable operating modes of the holding brake is
restricted. Only the following operating modes function:
Directly with brake module (C02580, selection 1
) and
Direct switching externally (C02580, selection 11
)
Stop!
It is only permissible to activate controlled operation of synchronous machines if the
following parameters have been set correctly, in addition to correct assignment of the
encoder image and the motor's rotating field:
Motor control SC, "Servo control of sync motor" (C00006, selection 1
)
Pole position of the motor encoder (C00058
)
Motor data (C00081
... C00091)
Active resolver feedback or encoder feedback as motor encoder (C00420
... C00422)