Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 429
11 Basic drive functions
11.6 Homing
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Mode 1: neg. direction - via home mark - to TP
Procedure:
1. Movement in negative direction with profile data set 1.
2. Positive edge at HM_bHomingMark activates profile data set 2 for the further reference search.
3. Negative edge at HM_bHomingMark enables home position detection.
4. The following positive edge of the encoder zero pulse/touch probe sensor sets the reference.
5. Absolute positioning to target position (C02643
) with profile data set 2 (if C02641 ="0").
Mode 2: pos. direction - reversing to limit switch - via home mark - to TP
Procedure:
1. Movement in positive direction with profile data set 1.
2. Reversing to positive travel range limit switch.
3. Positive edge at HM_bHomingMark activates profile data set 2 for the further reference search.
4. Negative edge at HM_bHomingMark enables home position detection.
5. The following positive edge of the encoder zero pulse/touch probe sensor sets the reference.
6. Absolute positioning to target position (C02643
) with profile data set 2 (if C02641 ="0").
Touch probe/zero pulse
 Reference switch
1
0
1
Touch probe/zero pulse
 Reference switch
 Positive travel range limit switch
1
0
1
2
Vista de página 428