Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 819
14 Parameter reference
14.2 Parameter list | C00807
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00807
C00808
C00809
C00810
C00811
Parameter | Name:
C00807 | MCTRL_dnTorqueHighLimit
Data type: INTEGER_32
Index: 23768
d
= 5CD8
h
Internal motor control (MCTRL) signal
Display range (min. value | unit | max. value)
-21474836.47 Nm 21474836.47
Read access Write access CINH PLC STOP No transfer Scaling factor: 100
Parameter | Name:
C00808 | MCTRL_dnPosCtrlOutLimit
Data type: INTEGER_32
Index: 23767
d
= 5CD7
h
Internal motor control (MCTRL) signal
Display range (min. value | unit | max. value)
-480000 rpm 480000
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C00809 | MCTRL_dnTorqueCtrlAdapt
Data type: INTEGER_32
Index: 23766
d
= 5CD6
h
Internal motor control (MCTRL) signal
Display range (min. value | unit | max. value)
-200.00 % 200.00
Read access Write access CINH PLC STOP No transfer Scaling factor: 100
Parameter | Name:
C00810 | MCTRL_dnSpeedCtrlAdapt
Data type: INTEGER_32
Index: 23765
d
= 5CD5
h
Internal motor control (MCTRL) signal
Display range (min. value | unit | max. value)
-200.00 % 200.00
Read access Write access CINH PLC STOP No transfer Scaling factor: 100
Parameter | Name:
C00811 | MCTRL_dnPosCtrlAdapt
Data type: INTEGER_32
Index: 23764
d
= 5CD4
h
Internal motor control (MCTRL) signal
Display range (min. value | unit | max. value)
-200.00 % 200.00
Read access Write access CINH PLC STOP No transfer Scaling factor: 100