14 Parameter reference
14.2 Parameter list | C00954
824
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00954
C00955
C00957
Parameter | Name:
C00954 | VFC: Activat. interpol. point n
Data type: UNSIGNED_32
Index: 23621
d
= 5C45
h
From software version V3.0
V/f control
Selection list
0Off
1On
Subcodes Lenze setting Info
C00954/1 1: On
C00954/2 1: On
C00954/3 1: On
C00954/4 1: On
C00954/5 1: On
C00954/6 1: On
C00954/7 1: On
C00954/8 1: On
C00954/9 1: On
C00954/10 1: On
C00954/11 1: On
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C00955 | VFC: Vmax reduction
Data type: UNSIGNED_32
Index: 23620
d
= 5C44
h
From software version V3.0
V/f control
Setting range (min. value | unit | max. value) Lenze setting
0 V 500 0V
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C00957 | VFC: VVC current setpoint
Data type: INTEGER_32
Index: 23618
d
= 5C42
h
From software version V3.0
V/f control
Setting range (min. value | unit | max. value) Lenze setting
0.00 A 1500.00 0.00 A
Read access Write access CINH PLC STOP No transfer Scaling factor: 100