5.5 Sensorless vector control (SLVC)
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5. Evaluate the step response:
6. Change the gain Vp under C00075
and the reset time Tn under C00076.
7. Repeat steps 4 ... 6 until the optimum step response of the motor current is reached.
In the optimised state the current rise time typically is 0.5 ... 1 ms.
8. After the optimisation has been completed, deactivate the test mode again (C00398
="0:
Test mode deactivated").
9. Save parameter set (C00002
= "11: Save start parameters").
I
t
I
t
I
t
I
t
I
t
I
t
I
t
I
t
I
t
Vp < Vp opt. Vp = Vp opt. Vp > Vp opt.
Tn < Tn opt.
Tn = Tn opt.
Tn > Tn opt.