14 Parameter reference
14.2 Parameter list | C00783
816
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00783
C00784
C00786
C00787
C00788
Parameter | Name:
C00783 | MCTRL_dwMotorVoltageAct
Data type: UNSIGNED_32
Index: 23792
d
= 5CF0
h
Internal motor control (MCTRL) signal
Display range (min. value | unit | max. value)
0 V 2000
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C00784 | MCTRL_dnMotorFreqAct
Data type: INTEGER_32
Index: 23791
d
= 5CEF
h
Internal motor control (MCTRL) signal
Display range (min. value | unit | max. value)
-800.0 Hz 800.0
Read access Write access CINH PLC STOP No transfer Scaling factor: 10
Parameter | Name:
C00786 | MCTRL_dnIxtLoad
Data type: INTEGER_32
Index: 23789
d
= 5CED
h
Internal motor control (MCTRL) signal
Display range (min. value | unit | max. value)
-200.00 % 200.00
Read access Write access CINH PLC STOP No transfer Scaling factor: 100
Parameter | Name:
C00787 | MCTRL_dnFlyingSpeedAct
Data type: INTEGER_32
Index: 23788
d
= 5CEC
h
Internal motor control (MCTRL) signal
Display range (min. value | unit | max. value)
-480000 rpm 480000
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C00788 | MCTRL_dwMaxEffMotorTorque
Data type: INTEGER_32
Index: 23787
d
= 5CEB
h
Internal motor control (MCTRL) signal
Display range (min. value | unit | max. value)
0.000 Nm 2147483.647
Read access Write access CINH PLC STOP No transfer Scaling factor: 1000