9 "CAN on board" system bus
9.2 Possible settings by DIP switch
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
9.2.2 Setting the baud rate
The baud rate can be set via code C00351 or with the DIP switches a to d:
Tip!
The baud rate resulting from the setting of the DIP switches at the last mains switching is
displayed in C00349/2
.
Switch positions Baud rate
d c b a
OFF ON ON OFF 10 kbps
OFF ON OFF ON 20 kbps
OFF OFF ON ON 50 kbps
OFF OFF ON OFF 125 kbps
OFF OFF OFF ON 250 kbps
OFF OFF OFF OFF 500 kbps
ON ON ON OFF 800 kbps
OFF ON OFF OFF 1 Mbps
OFF ON ON ON Automatic recognition
Note!
Switch the voltage supply of the basic device off and then on again to activate altered
settings.