Lenze 9400 Manual do Utilizador Página 801

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 954
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 800
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 801
14 Parameter reference
14.2 Parameter list | C00597
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00597
C00598
C00599
C00600
Parameter | Name:
C00597 | Resp. to motor phase failure
Data type: UNSIGNED_32
Index: 23978
d
= 5DAA
h
Response to activation of motor phase failure monitoring
Selection list (Lenze setting printed in bold)
1Fault
2Trouble
5 Warning
4 Warning locked
3 Quick stop by trouble
0 No response
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C00598 | Resp. to open circuit AIN1
Data type: UNSIGNED_32
Index: 23977
d
= 5DA9
h
Response if with master current at AIN1 and "LifeZero" mode (±4...±20mA) the current is in the non-permitted range
(-4 ... +4 mA).
Selection list (Lenze setting printed in bold)
1Fault
2Trouble
3 Quick stop by trouble
4 Warning locked
5 Warning
6 Information
0 No response
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C00599 | Motor phase failure threshold
Data type: INTEGER_32
Index: 23976
d
= 5DA8
h
Current value for activating the Motor phase failure monitoring
• In [%] relating to the maximum device current (display in C00789).
• The response to be triggered by the monitoring can be selected in C00597
.
Setting range (min. value | unit | max. value) Lenze setting
1.0 % 100.0 5.0 %
Read access Write access CINH PLC STOP No transfer Scaling factor: 10
Parameter | Name:
C00600 | Resp. to DC bus overvoltage
Data type: UNSIGNED_32
Index: 23975
d
= 5DA7
h
Response to DC bus overvoltage
Braking operation
Selection list (Lenze setting printed in bold)
1Fault
2Trouble
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Vista de página 800
1 2 ... 796 797 798 799 800 801 802 803 804 805 806 ... 953 954

Comentários a estes Manuais

Sem comentários