6 Encoder evaluation
6.3 Parameter setting
242
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
How to get to the dialog for setting the encoder evaluation parameters:
1. Go to the Project view of the »Engineer« and select the 9400 HighLine controller.
2. Select the Application parameters tab from the Workspace.
3. Click the button All basic functions in the Overview dialog level.
4. Click the button Encoder evaluation in the dialog level Overview All basic functions.
Parameterisation dialog in the »Engineer«
See also: Parameterising motor encoder ( 126)
C02765 ENC_bError -
C02862/1
Resolver: cos gain 100 %
C02862/1
Resolver: sine gain 100 %
C02863
Resolver: Angle correction 0
Parameter Info Lenze setting
Value Unit
Greyed out = display parameter