14 Parameter reference
14.2 Parameter list | C00619
806
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00619
C00620
C00621
Parameter | Name:
C00619 | Resp. to motor current > C00620
Data type: UNSIGNED_32
Index: 23956
d
= 5D94
h
Response if the ultimate motor current I_ult parameterised in C00620 is reached.
Selection list (Lenze setting printed in bold)
1Fault
2Trouble
5 Warning
4 Warning locked
3 Quick stop by trouble
0 No response
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C00620 | Ultimate motor current I_ult
Data type: UNSIGNED_32
Index: 23955
d
= 5D93
h
Limit value to protect the motor from destruction or influence of the rated data.
• This limit value must not be travelled cyclically in the drive process.
• The maximum current parameterisable in C00022
should have a sufficient distance from this limit value.
• If the set limit value is exceeded, the error response parameterised in C00619
is carried out for motor protection.
Setting range (min. value | unit | max. value) Lenze setting
0.0 A 3000.0 3000.0 A
Read access Write access CINH PLC STOP No transfer Scaling factor: 10
Parameter | Name:
C00621 | Resp. to encoder pulse deviation
Data type: UNSIGNED_32
Index: 23954
d
= 5D92
h
From software version V1.5
Response to be triggered by angular drift monitoring
Angular drift monitoring
Selection list (Lenze setting printed in bold)
1Fault
2Trouble
5 Warning
4 Warning locked
3 Quick stop by trouble
13 Quick Stop open loop by trouble
0 No response
Read access Write access CINH PLC STOP No transfer Scaling factor: 1